About Process to Signal (4 to 20) mA

Status Instruments’ free App for converting a process signal value, in any engineering unit, into a control signal in milli amps, milli volts, or volts. For use in temperature measurement, process control, and signal...

Status Instruments’ free App for converting a process signal value, in any engineering unit, into a control signal in milli amps, milli volts, or volts.
For use in temperature measurement, process control, and signal conditioning


The input engineering range and output signal range are entered into the calculator.


Typical use would be for a control or alarm system monitoring the temperature in a vessel. A temperature transmitter would be used to generate a mA signal to represent °C.

Example
Input range in engineering units (0 to 100)°C ; output signal range (4 to 20) mA [sometimes given as 4-20mA]

A point input value can entered in °C and the corresponding output signal value in mA calculated.

An output signal value in mA can entered and the corresponding input temperature in °C calculated

Typical engineering units
inH2, inHg, ftH2O, mmH2O, mmHg, psi, bars, mbar, g/sqcm, kg/sqcm, Pa, KPa, Torr, Atmosph, Cuft/min , gal/min, L/min, Impgal/min, Cum/h, ft/s, m/s, gals/s, MMgal/d, L/s, ML/d, Cuft/s, Cuft/d, Cum/s, Cum/d, Impgal/h, Impgal/d, Deg C, Deg F, Deg R, Kelvin, Mv, ohms, Hz, mA, gal, L, Impgal, Cum, Ft, M, Bbl, In, Cm, Mm, Min, S, H, D, cSt, cP, uMho, %, V, pH, g, kg, Met Ton, Lb, STon, LTon, mS/cm, uS/cm,N, Nm, g/s, g/min, g/h, kg/s, kg/min,kg/h,kg/d, Met Ton/min, Met Ton/h, Met Ton/d, lb/s, lb/min, lb/h, lb/d, STon/min, STon/h, STon/d, LTon/h, LTon/d, Datherm, SGU, g/Cucm, kg/Cum, lb/gal, lb/Cuft, g/mL, kg/L, g/L, lb/Cuin, STon/Cutd, degTwad, degBrix, degBaum hv, degBaum lt, degAPI, % sol-wt, % sol-vol, degBall, proof/vol, proof/mass, bush, Cuyd, Cuft, Cuin, in/s, in/min, ft/min, deg/s, rev/s, rpm, m/h, NmlCum/h, NmlL/h, StdCuft/min, bbl(liq), Cuft/hr, Cum/min, bbl/s, bbl/m, bbl/h, bbl/d, gal/h, impgal/s, L/h, Ppm, Mcal/h, Mj/h, Btu/h, Deg, Rad, inH2O @ 60°C, ug/L, ug/Cum,%Cs, Vol%, % Stm Quad, ft.in 16, Cuft/Lb, pF, mL/L, uL/L, % plato, % LEL, Mcal, KO, MJ, Btu, NmlCum, Nm/L, StdCuft, Ppb, gal/d, hL, MPa, inH2O @ 4°C, mmH2O @ 4°C, & uV.


Note: the values represent ideals, no tolerances have been applied and no allowances for input source errors, or output measurement equipment errors have been used.



Previous Versions

Here you can find the changelog of Process to Signal (4 to 20) mA since it was posted on our website on 2016-12-23 23:23:39. The latest version is 1.5.0 and it was updated on 2024-04-22 18:43:43. See below the changes in each version.

Process to Signal (4 to 20) mA version 1.5.0
Updated At: 2015-06-18
Changes: - Bug Fixes,- New Features,- Smaller file size,- Easier to calculate,- Now supports API level 7 and above,- New Layout


Related Apps

Here you can find apps that are similar with Process to Signal (4 to 20) mA.



Disclaimer

Official Google Play Link


We do not host Process to Signal (4 to 20) mA on our servers. We did not scan it for viruses, adware, spyware or other type of malware. This app is hosted by Google and passed their terms and conditions to be listed there. We recommend caution when installing it.

The Google Play link for Process to Signal (4 to 20) mA is provided to you by apps112.com without any warranties, representations or guarantees of any kind, so access it at your own risk.

If you have questions regarding this particular app contact the publisher directly. For questions about the functionalities of apps112.com contact us.

BarCode2D-PNG


Click stars to rate this APP!

Users Rating:  
  0.0/5     0
Downloads: 2
Updated At: 2024-04-22 18:43:43
Publisher: Status Instruments
Operating System: Android
License Type: Free